Part Number Hot Search : 
N320CB1 LRD35 A2810 C3461 1N456ATR 74VHC1G C74HC2 FN1198
Product Description
Full Text Search
 

To Download CXA10 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CXA10 Series
DC/DC CONVERTERS * * * * * * * * * 10W DC/DC Converters
Single and dual output
1
4:1 input voltage range Approved to EN60950, UL1950, CSA C22.2 No. 950 Operating ambient temperature of -40C to +70C in still air High demonstrated reliability with conservative component deratings Complies with ETS 300 019-1-3/2-3 Complies with ETS 300 132-2 input voltage and current requirements Fully compliant with ETS 300 386-1 Pin compatible with NFC10 and BXA10 series Basic insulation system (input to output)
The CXA10 series comprising of five different models delivers single and dual output voltages covering 3.3V, 5V, 12V, 5V, 12 and 15V. The series has a wide 4:1 input voltage range of 18 to 75VDC. The CXA10 has been designed as a competitive open-frame alternative for the communications market. The product is supplied in the industry standard footprint of 2.0 x 1.0 x 0.394 inches. Other product features include overvoltage protection, short circuit protection and remote on/off. All components are placed in a fully automated environment. Planar magnetics are used in the design to improve the reliability and reduce the profile of the DC/DC converter. The series has full international safety approval to EN60950 and UL1950 reducing system compliance costs, and it has a basic insulation system from input to output making it suitable for a wide variety of applications.
2 YEAR WARRANTY All specifications are typical at nominal input, full load at 25C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS Voltage accuracy Line regulation (LL to HL) Load regulation (not incl. cross reg.) Min. load Ripple and noise 20MHz bandwidth Temperature coefficient Overvoltage protection Short circuit protection Short <20m Transient response Load cross regulation INPUT SPECIFICATIONS Input voltage range Input fuse Max. input rise and fall time UVLO turn ON voltage UVLO turn OFF voltage Remote ON/OFF Logic compatibility ON OFF 48Vin nominal (See Note 10) 48V ETS300 132-2 (See Note 5) (See Note 5) 18 to 75VDC 1.5A HRC 5V/ms 94% 86% (See Note 7) CMOS/TTL/Open Collector Open circuit <1VDC Clamp type Hiccup Min. load to FL Min. load to FL (See Note 1) Singles/dual positives Dual negatives Full load to minimum load All outputs 3.3V and 5.0V All others All models 1.0% 0.1% 0.2% 0.15% 10% 30mV pk-pk 60mV pk-pk 12mV rms 0.01%/C (See table and Notes 3, 4) Continuous auto. recovery 1.0% 5.0%
EMC CHARACTERISTICS ETS 300 386-1 table 5 Conducted emissions Radiated emissions ESD air ESD contact Surge (500V) Fast transients Radiated immunity Conducted immunity EN55022 (See Note 6) EN55022, external filter, VDE0878, 48V models See Application Note 100 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3, 4 EN61000-4-4, level 3, 4 EN61000-4-3, level 3 EN61000-4-6, level 3 Level A Level B
GENERAL SPECIFICATIONS Efficiency Isolation voltage Switching frequency Approvals and standards (See Notes 7,8,9,10,11) Material flammability Weight MTBF (Representative model 48S05 @ 48Vin) See table Input/output test voltage 1500VDC Fixed 400kHz EN60950, UL1950 CSA C22.2 No. 950 UL94V-0 12g (0.42 oz) MIL-HDBK-217F 456,621 hours Parts stress method Ground Benign @ 25C
ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient -40C to +70C, temperature See curves Non-operating -55C to +105C ETS 300 019-2-3 Classes T3.1 to T3.5 Air temperature Low: IEC 68-2-1 -40C High: IEC 68-2-2 +70C Change: IEC 68-2-14 -40C to +70C Relative humidity IEC 68-2-56 10% to 100% RH IEC 68-2-30 Condensation Vibration, Class 3M5 IEC68-2-6 2 to 9Hz, 3mm disp. 9 to 200Hz 1g MIL-STD-202F Method 204 cond. A Shock, Class 3M5 IEC-68-2-29 Method 213B cond. A MIL-STD-202F
File Name: CXA10.PDF Rev: 11 Jan 2002
CXA10 Series
DC/DC CONVERTERS 10W DC/DC Converters
INPUT VOLTAGE 18-75VDC 18-75VDC 18-75VDC 18-75VDC 18-75VDC 18-75VDC Notes OUTPUT VOLTAGE 3.3V 5.0V 12V 5V 12V 15V
Single and dual output
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OVERVOLTAGE PROTECTION (3,4) 3.9V 6.8V 16V 6.8V 16V 19V
OUTPUT CURRENT (MAX.) (9) 2.4A 2.0A 0.83A 1.0A 0.41A 0.33A
TYPICAL EFFICIENCY 78% 81% 83% 81% 83% 81%
MODEL NUMBER (7) CXA10-48S3V3 CXA10-48S05 CXA10-48S12 CXA10-48D05 CXA10-48D12 CXA10-48D15
Negative output voltage deviation when positive load is changed. Guaranteed minimum output voltage range. TVS spec: See Application Note 100 on our web site. On dual output models, OVP protection is on negative outputs only. With respect to minimum input voltage. With one external ITW Paktron 4.7F film capacitor across the input. For units with optional remote ON/OFF, please add the suffix `-S' to the model number, e.g. CXA10-48S05-S. Additional alphanumeric suffixes maybe added to indicate minor modifications not affecting the safety approvals. 8 Unit provides basic insulation up to the 75VDC maximum input voltage. 9 Maximum continuous output power not to exceed 10 Watts. 7.9 Watts for the 3V3 model. 10 User must provide 1.5A in line fuse in order to comply with safety approvals. 11 Maximum temperature on components Q100, CR101, CR102 not to exceed 120C. See Application Note 100 for details.
1 2 3 4 5 6 7
0.100 (2.54)
0.400 (10.16)
0.400 (10.16)
0.020 (0.50)
O0.040 0.002 Dia. (O1.02 0.05)
3 0.020 (0.5) 2.000 (50.80) 0.800 (20.32)
4
5
1
2
6
0.600 (15.24) OPENFRAME HEIGHT
0.400 (10.16)
0.200 (5.08)
0.300 (7.62)
0.142 (3.60) 0.012 (0.3)
0.394 (10.00) Max. 0.012 (0.3) 0.536 (13.60)
CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible.
1.000 (25.40) 0.020 (0.5)
ALL DIMENSIONS IN INCHES (mm) Tolerance on all dimensions of 0.005 (0.127) Unless otherwise specified
PIN CONNECTIONS PIN NUMBER 1 2 6* 3 4 5 SINGLE OUTPUT + Input - Input Remote ON/OFF + Output No Pin - Output DUAL OUTPUT + Input - Input Remote ON/OFF + Output
0% Output Power (%) 100%
DERATING CURVE
(Output Power %)
75%
50%
25% 27.5%
Common - Output
-40C -30C -20C -10C 0C
10C 20C 30C 40C 50C 60C 70C 80C
90C 100C
AMBIENT TEMPERATURE (C)
Figure 1: Natural Convection (0.1m/s) Typical derating - See Application Note 100
* Optional remote ON/OFF pin. Please add the suffix `-S' to the model number, e.g. CXA10-48S05-S (See Note 7).
Data Sheet (c) Artesyn Technologies(R) 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:
Application Note
Longform Data Sheet
www.artesyn.com
File Name: CXA10.PDF Rev: 11 Jan 2002


▲Up To Search▲   

 
Price & Availability of CXA10

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X